SINGLE-TONE BURST GENERATOR
Schematic:
Notes:
The tone burst generator
supplies a tone for one-half second after the power supply is activated; its
intended use is a communications network alert signal. Cessation of the tone is
accomplished at the SCR, which shunts the timing capacitor C1 charge current
when activated. The SCR is gated on when C2 charges up to the voltage which
occurs in 0.5 seconds. Since only 70 uA are available
for triggering, the SCR must be sensitive enough to trigger at this level. The
triggering current can be increased, of course, by reducing R2 (and increasing
C2 to keep the same time constant). If the tone duration must be constant under
widely varying supply voltage conditions, the optional Zener diode regulator
circuit can be added, along with the new value for R2R2' = 82 kohms. If the SCR is replaced by an npn transistor, the tone can be switched on and off
at will at the transistor base terminal.
Return to Signal Circuits